Chemical ionization mass spectrometry utilizing ammonium ions (NH4+CIMS) for measurements of organic compounds in the atmosphere

Pubblico Deposited

Contenuto scaricabile

Scarica il pdf
https://scholar.colorado.edu/concern/articles/r494vm93j
Abstract
  • We describe the characterization and field deployment of chemical ionization mass spectrometry (CIMS) using a recently developed focusing ion-molecule reactor (FIMR) and ammonium–water cluster () as the reagent ion (denoted as CIMS). We show that  is a highly versatile reagent ion for measurements of a wide range of oxygenated organic compounds. The major product ion is the cluster with  produced via ligand-switching reactions. Other product ions (e.g., protonated ion, cluster ion with , with H3O+, and with ) are also produced, but with minor fractions for most of the oxygenated compounds studied here. The instrument sensitivities (ion counts per second per part per billion by volume, cps ppbv−1) and product distributions are strongly dependent on the instrument operating conditions, including the ratio of ammonia (NH3) and H2O flows and the drift voltages, which should be carefully selected to ensure  as the predominant reagent ion and to optimize sensitivities. For monofunctional analytes, the  chemistry exhibits high sensitivity (i.e., >1000 cps ppbv−1) to ketones, moderate sensitivity (i.e., between 100 and 1000 cps ppbv−1) to aldehydes, alcohols, organic acids, and monoterpenes, low sensitivity (i.e., between 10 and 100 cps ppbv−1) to isoprene and C1 and C2 organics, and negligible sensitivity (i.e., <10 cps ppbv−1) to reduced aromatics. The instrumental sensitivities of analytes depend on the binding energy of the analyte– cluster, which can be estimated using voltage scanning. This offers the possibility to constrain the sensitivity of analytes for which no calibration standards exist. This instrument was deployed in the RECAP campaign (Re-Evaluating the Chemistry of Air Pollutants in California) in Pasadena, California, during summer 2021. Measurement comparisons against co-located mass spectrometers show that the  CIMS is capable of detecting compounds from a wide range of chemical classes. The  CIMS is valuable for quantification of oxygenated volatile organic compounds (VOCs) and is complementary to existing chemical ionization schemes.

Creator
Date Issued
  • 2022
Academic Affiliation
Journal Title
Journal Issue/Number
  • 24
Journal Volume
  • 15
Ultima modifica
  • 2025-01-11
Resource Type
Dichiarazione dei diritti
License
DOI
ISSN
  • 1867-8548
Language

Relazioni

Articoli