Article
Accuracy Comparison of Absolute Optical Frequency Measurement between Harmonic-Generation Synthesis and a Frequency-Division Femtosecond Comb 公开 Deposited
https://scholar.colorado.edu/concern/articles/bv73c1034
- Abstract
Using an iodine-stabilized He-Ne laser as a transfer oscillator, we compare absolute measurements of the optical frequency from a traditional frequency synthesis chain based on harmonic generation and from the frequency division technique of an ultrawide bandwidth femtosecond frequency comb. The agreement between these two measurements, both linked to the Cs standard, is 220±770 Hz, yielding a measurement accuracy of 1.6×10−12. We report 473612353604.8±1.2 kHz as a preliminary updated value of the absolute frequency of the “ f ” component for the He-Ne laser international standard at 633 nm.
- Creator
- Date Issued
- 2000-10-30
- Academic Affiliation
- Journal Title
- Journal Issue/Number
- 18
- Journal Volume
- 85
- File Extent
- 3797-3800
- 最新修改
- 2020-01-14
- Resource Type
- 权利声明
- DOI
- ISSN
- 0031-9007
- Language
关联
单件
缩略图 | 标题 | 上传日期 | 公开度 | 行动 |
---|---|---|---|---|
accuracyComparisonOfAbsoluteOpticalFrequencyMeasurementBet.pdf | 2019-12-05 | 公开 | 下载 | |
accuracyComparisonOfAbsoluteOpticalFrequencyMeasurementBet.pdf | 2019-12-05 | 公开 | 下载 |